RRS08 1301

Objects are not guaranteed to remain at the same index for different card firmware revisions.
Control software must provide runtime user configurable object indices or use auto-discovery.
Menu itemRangeDefaultGroupIndexType
Card namemax. length 8RRS0810string
User labelmax. length 1611string
Card descriptionmax. length 16Rack Controller12string
Software revmax. length 4130113string
Hardware revmax. length 4empty string14string
Product codemax. length 10941040001015string
Serial numbermax. length 16PR03310116string
Card IDmax. length 16DA000016B23AF80117string
Keymax. length 15empty string18string
Featuresmax. length 8000001D819string
SNMPOption
OK
Option110enumeration
IP_ConfManual
DHCP
DHCP20enumeration
mIP0.0.0.0..255.255.255.2550.0.0.021ip address
mNM0.0.0.0..255.255.255.255255.255.255.022ip address
mGW0.0.0.0..255.255.255.2550.0.0.023ip address
BroadcastsOff
On
On24enumeration
ForwardingOff
On
Off25enumeration
FW0.0.0.0..255.255.255.2550.0.0.026ip address
NetwPrefix0bit..30bit24bit27integer
ErrorThreshold0..2551028byte
Redund_Pwr_TestOff
On
Off29enumeration
Trap-Dest_0Off
On
Off210enumeration
TD_00.0.0.0..255.255.255.2550.0.0.0211ip address
Trap-Dest_1Off
On
Off212enumeration
TD_10.0.0.0..255.255.255.2550.0.0.0213ip address
IP_AddrManual
DHCP Asking
DHCP Leased
DHCP Infin
DHCP Asking30enumeration
IP0.0.0.0..255.255.255.2550.0.0.031ip address
NM0.0.0.0..255.255.255.2550.0.0.032ip address
GW0.0.0.0..255.255.255.2550.0.0.033ip address
PSU_TopNA
OK
NA34enumeration
PSU_BottomNA
OK
NA35enumeration
Temp_Left-999deg...127deg.-999deg.36integer
Temp_Right-999deg...127deg.-999deg.37integer
Temp-999deg...127deg.-999deg.38integer
Temp_Front-999deg...128deg.-999deg.39integer
SPF_StatusIdle
Busy
Done
Error
Idle310enumeration
SPF_Progress0%..100%100%311byte
Rx_Packet_Loss0..00312long
Main_Ref_PwrNA
OK
NA313enumeration
MIB_S0max. length 11RRS08v13NRC314string
MIB_S1max. length 11empty315string
MIB_S2max. length 112TG10v090316string
MIB_S3max. length 11empty317string
MIB_S4max. length 11empty318string
MIB_S5max. length 11GQW20v340319string
MIB_S6max. length 11empty320string
MIB_S7max. length 11empty321string
MIB_S8max. length 11GXG41v040322string
Announcementstags 0x1, 0x81
Announcements on, Announcements off
priority 0..255
1 ?
40alarm
PSU_Ttags 0x7, 0x87
PSU_ERROR, PSU_OK
priority 0..255
0 ?
41alarm
PSU_Btags 0x7, 0x87
PSU_ERROR, PSU_OK
priority 0..255
0 ?
42alarm
Temperaturetags 0xa, 0x8a
TEMP_TOO_HIGH, TEMP_OK
priority 0..255
0 ?
43alarm
Ref_Backuptags 0x9, 0x89
REF_BACKUP_ERROR, REF_BACKUP_OK
priority 0..255
0 ?
44alarm
Card-Presencetags 0x14, 0x94
CARD_INSERTED, CARD_REMOVED
priority 0..255
1 ?
45alarm